The Key To

Quality Switches

Siren Specifications

Standard with the 14UR1A are four two-tone codes, three of which are activation with the fourth one being the cancel code. Each of the three programmable codes have timers that can control the output relays. These timers can be programmed to an on time, off time and the total time, this will allow the siren to cycle for the specified alert notifications. The relay timers can be programmed anywhere from 1 sec to 3 minutes in 1 sec increments. Also the 14UR1A has an internal thermostat and heater which helps maintain a minimum temperature. Options for the Siren Controller include a DTMF decoder and a programming kit. The programming kit allows you to set the tome frequencies, and relay times. Each programming kit includes software and cable.

GENERAL

Enclosure:     

            

Size:

 

Weight:

 

Temperature:

 

Input Voltage:

 

Thermostat Heater:

 

Output Relays:

 

 

Antenna:

NEMA 4X Metal        

 

15.75” x 11.8” x 5.9”

 

16lbs.

 

-25  F tp + 140 F

 

10—304 VAC: .25 Amp.

 

86 F

 

2 SPDT, 12AGW Max.

10 Amp @ 250VAC

 

1/4 Wave—Top Mount

 

Receiver

Frequency Range:

 

Sensitivity:

     12dB SINAD

 

Intermodulation:

 

Spurious Response:

 

Selectivity:

 

 

Antenna Impedance:

142-174MHz    450-490MHz

 

.30uV @ 12.5 KHz

.28uV @ 25 KHz

 

70dB              70dB

 

65dB              65dB

 

-60dB @ 12.5KHz

-70dB @ 25KHz

 

50 Ohms

Decoder

Functions:                                  3 on codes

                                                    1 cancel code

 

Each on code may be programmed for steady on or cycle on/off. Each code may control relay 1, relay 2 or both.

 

Timing:

    On/Off Cycle Duration:        1 sec. to 30 min.

                                                     In 1 sec. increments

 

    Total Duration:                      1 sec. to 30 min.

                                                     In 1 sec. increments

 

Two-tone:

    Frequency Range:                300 to 3000Hz

   

    Tone Timing:                         1 sec./1 sec.

                                                    1 sec./3 sec.

DTMF (optional):

    Digit Length:                          1 to 14 digits

 

    Inter-Digit Timeout:               200ms to 12 sec.